Overview
The FG-2800 Frequency Counter is a compact, pocket-size test instrument, designed for ease of use and dependable performance. Advanced features such as Field Strength Measurement are incorporated in the FG-2800.
50W input for full range 1MHz to 2.8GHz coverage High speed 250MHz direct count with 1Hz per second resolution 10 digit LCD display Ultra-sensitive synchronous detector bargraph with 16 segment display of RF signal strength Low power consumption 6 hour NiCd battery operation Low battery indicator Hold switch locks display Supplied with telescoping whp antenna and AC wall adapter Amplifier: 50W/Impedance: 50W, VSWR<2:1/Range: 1MHz - 2.8GHz/ Sensitivity: <0.8mV@100MHz, <6mV@250MHz, <7mV@1GHz, <100mV@2.4GHz/ Maximum Input: 15dBm Cabinet: Extruded aluminum, black paint finish Display: 10 Digit Liquid Crystal Display Size: 61/8" (H) x 25/8" (W) x 1¼" (D) Battery: Internal 4 "AA" 600mAH NiCd battery pack Power: 9VDC, 500mA wall plug adapter Time Base: <1ppm typ. at room temperature REQUENCY DISPLAY RESOLUTION Range: 250MHz/Gate Time: 0.0625 sec., 0.25 sec., 1 sec., 4 sec./LSD: 10Hz, 1Hz, 0.1Hz, 0.1Hz/Range: 2.8GHz/Gate Time: 0.0625 sec., 0.25 sec., 1 sec., 4 sec./LSD: 1000Hz, 100Hz, 10Hz, 10Hz RF Signal Strength Bargraph Frequency: 27MHz, 150MHz, 800MHz/ 1st Segment: 7mV, 5mV, 10mV/Full Scale: 100mV, 90mV, 200mV
|